1.
J Cardiovasc Dev Dis ; 11(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38667743

RESUMEN

Heart failure (HF) is a growing issue in developed countries; it is often the result of underlying processes such as ischemia, hypertension, infiltrative diseases or even genetic abnormalities. The great majority of the affected patients present a reduced ejection fraction (≤40%), thereby falling under the name of "heart failure with reduced ejection fraction" (HFrEF). This condition represents a major threat for patients: it significantly affects life quality and carries an enormous burden on the whole healthcare system due to its high management costs. In the last decade, new medical treatments and devices have been developed in order to reduce HF hospitalizations and improve prognosis while reducing the overall mortality rate. Pharmacological therapy has significantly changed our perspective of this disease thanks to its ability of restoring ventricular function and reducing symptom severity, even in some dramatic contexts with an extensively diseased myocardium. Notably, medical therapy can sometimes be ineffective, and a tailored integration with device technologies is of pivotal importance. Not by chance, in recent years, cardiac implantable devices witnessed a significant improvement, thereby providing an irreplaceable resource for the management of HF. Some devices have the ability of assessing (CardioMEMS) or treating (ultrafiltration) fluid retention, while others recognize and treat life-threatening arrhythmias, even for a limited time frame (wearable cardioverter defibrillator). The present review article gives a comprehensive overview of the most recent and important findings that need to be considered in patients affected by HFrEF. Both novel medical treatments and devices are presented and discussed.

2.
Heart Rhythm ; 21(5): 555-561, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38242222

RESUMEN

BACKGROUND: There are limited real-world data on the extended prognosis of patients with drug-induced type 1 Brugada electrocardiogram (ECG). OBJECTIVE: We assessed the clinical outcomes and predictors of life-threatening arrhythmias in patients with drug-induced type 1 Brugada ECG. METHODS: This multicenter retrospective study, conducted at 21 Italian and Swiss hospitals from July 1997 to May 2021, included consecutive patients with drug-induced type 1 ECG. The primary outcome, a composite of appropriate ICD therapies and sudden cardiac death, was assessed along with the clinical predictors of these events. RESULTS: A total of 606 patients (mean age 49.7 ± 14.7 years; 423 [69.8%] men) were followed for a median of 60.3 months (interquartile range 23.0-122.4 months). Nineteen patients (3.1%) experienced life-threatening arrhythmias, with a median annual event rate of 0.5% over 5 years and 0.25% over 10 years. The SCN5A mutation was the only predictor of the primary outcome (hazard ratio 4.54; P = .002), whereas a trend was observed for unexplained syncope (hazard ratio 3.85; P = .05). In patients who were asymptomatic at presentation, the median annual rate of life-threatening arrhythmias is 0.24% over 5 years and increases to 1.2% if they have inducible ventricular fibrillation during programmed ventricular stimulation. CONCLUSION: In patients with drug-induced type 1 Brugada ECG, the annual risk of life-threatening arrhythmias is low, with the SCN5A mutation as the only independent predictor. Unexplained syncope correlated with worse clinical outcomes. Ventricular fibrillation inducibility at programmed ventricular stimulation significantly increases the median annual rate of life-threatening arrhythmias from 0.24% to 1.2% over 5 years.


Asunto(s)
Síndrome de Brugada , Electrocardiografía , Sistema de Registros , Humanos , Masculino , Síndrome de Brugada/fisiopatología , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/epidemiología , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Pronóstico , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Italia/epidemiología , Estudios de Seguimiento , Desfibriladores Implantables , Suiza/epidemiología , Factores de Tiempo , Tasa de Supervivencia/tendencias , Adulto
3.
Expert Rev Med Devices ; 20(11): 951-961, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37712650

RESUMEN

BACKGROUND: The prognosis for heart failure (HF) patients remains poor, with a high mortality rate, and a marked reduction in quality of life (QOL) and functional status. This study aims to explore the ongoing needs of HF management and the epidemiology of patients followed by Italian HF clinics, with a specific focus on cardiac contractility modulation (CCM). RESEARCH DESIGN AND METHODS: Data from patients admitted to 14 HF outpatients clinics over 4 weeks were collected and compared to the results of a survey open to physicians involved in HF management operating in Italian centers. RESULTS: One hundred and five physicians took part in the survey. Despite 94% of patients receive a regular follow-up every 3-6 months, available therapies are considered insufficient in 30% of cases. Physicians reported a lack of treatment options for 23% of symptomatic patients with reduced ejection fraction (EF) and for 66% of those without reduced EF. Approximately 3% of HF population (two patients per month per HF clinic) meets the criteria for immediate CCM treatment, which is considered a useful option by 15% of survey respondents. CONCLUSIONS: Despite this relatively small percentage, considering total HF population, CCM could potentially benefit numerous HF patients, particularly the elderly, by reducing hospitalizations, improving functional capacity and QOL.

4.
Europace ; 25(11)2023 11 02.
Artículo en Inglés | MEDLINE | ID: mdl-37490930

RESUMEN

AIMS: Infections resulting from cardiac implantable electronic device (CIED) implantation are severely impacting on patients' and on health care systems. The use of TYRXTM absorbable antibiotic-eluting envelope has proven to decrease major CIED infections within 12 months of CIED surgery. The aim is to evaluate the impact of the envelope use on infection-related clinical events in a real-world contemporary patient population. METHODS AND RESULTS: Data on patients undergoing CIED surgery were collected prospectively by participating centers of the One Hospital ClinicalService project. Patients were divided into two groups according to whether TYRXTM absorbable antibiotic-eluting envelope was used or not. Out of 1819 patients, 872 (47.9%) were implanted with an absorbable antibiotic-eluting envelope and included in the Envelope group and 947 (52.1%) patients who did not receive an envelope were included in the Control group. Compared to control, patients in the Envelope group had higher thrombo-embolic or hemorrhagic risk, higher BMI, lower LVEF and more comorbidities. During a mean follow-up of 1.4 years, the incidence of infection-related events was significantly higher in the control compared to the Envelope group (2.4% vs. 0.8%, P = 0.007). The five-year cumulative incidence of infection-related events was 8.1% in the control and 2.1% in the Envelope group (HR: 0.34, 95%CI: 0.14-0.80, P = 0.010). CONCLUSION: In our analysis, the use of an absorbable antibiotic-eluting envelope in the general CIED population was associated with a lower risk of systemic and pocket infection.


Asunto(s)
Desfibriladores Implantables , Cardiopatías , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Humanos , Desfibriladores Implantables/efectos adversos , Marcapaso Artificial/efectos adversos , Antibacterianos/uso terapéutico , Causalidad , Cardiopatías/complicaciones , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/prevención & control
5.
G Ital Cardiol (Rome) ; 24(8): 646-652, 2023 08.
Artículo en Italiano | MEDLINE | ID: mdl-37492872

RESUMEN

This review illustrates the pathophysiological aspects and available scientific evidence on molecular mechanisms about cardiac contractility modulation (CCM) therapy. The main advances in understanding the effect of this electrical therapy at cellular level in the heart are critically discussed in light of the data from clinical trials supporting the use of CCM therapy in patients with heart failure across a wide range of left ventricular ejection fraction values. This electrical therapy triggers a physiological cellular response leading to an improvement of cardiac performance and reverse ventricular remodeling, with no increase in oxygen consumption. The present review deals with the new potential applications of CCM for patients with chronic heart failure and paves the way for the development of a longitudinal Italian registry of patients implanted with this cardiac device.


Asunto(s)
Insuficiencia Cardíaca , Función Ventricular Izquierda , Humanos , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Resultado del Tratamiento , Contracción Miocárdica/fisiología , Insuficiencia Cardíaca/terapia , Cardiotónicos , Antiarrítmicos
6.
J Cardiovasc Electrophysiol ; 34(5): 1216-1227, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37087672

RESUMEN

INTRODUCTION: The assessment of the ventricular myocardial substrate critically depends on the size of mapping electrodes, their orientation with respect to wavefront propagation, and interelectrode distance. We conducted a dual-center study to evaluate the impact of microelectrode mapping in patients undergoing catheter ablation (CA) of ventricular tachycardia (VT). METHODS: We included 21 consecutive patients (median age, 68 [12], 95% male) with structural heart disease undergoing CA for electrical storm (n = 14) or recurrent VT (n = 7) using the QDOT Micro catheter and a multipolar catheter (PentaRay, n = 9). The associations of peak-to-peak maximum standard bipolar (BVc ) and minibipolar (PentaRay, BVp ) with microbipolar (BVµMax ) voltages were respectively tested in sinus rhythm with mixed effect models. Furthermore, we compared the features of standard bipolar (BE) and microbipolar (µBE) electrograms in sinus rhythm at sites of termination with radiofrequency energy. RESULTS: BVµMax was moderately associated with both BVc (ß = .85, p < .01) and BVp (ß = .56, p < .01). BVµMax was 0.98 (95% CI: 0.93-1.04, p < .01) mV larger than corresponding BVc , and 0.27 (95% CI: 0.16-0.37, p < .01) mV larger than matching BVp in sinus rhythm, with higher percentage differences in low voltage regions, leading to smaller endocardial dense scar (2.3 [2.7] vs. 12.1 [17] cm2 , p < .01) and border zone (3.2 [7.4] vs. 4.8 [20.1] cm2 , p = .03) regions in microbipolar maps compared to standard bipolar maps. Late potentials areas were nonsignificantly greater in microelectrode maps, compared to standard electrode maps. At sites of VT termination (n = 14), µBE were of higher amplitude (0.9 [0.8] vs. 0.4 [0.2] mV, p < .01), longer duration (117 [66] vs. 74 [38] ms, p < .01), and with greater number of peaks (4 [2] vs. 2 [1], p < .01) in sinus rhythm compared to BE. CONCLUSION: microelectrode mapping is more sensitive than standard bipolar mapping in the identification of viable myocytes in SR, and may facilitate recognition of targets for CA.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Masculino , Anciano , Femenino , Microelectrodos , Resultado del Tratamiento , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Taquicardia Ventricular/complicaciones , Arritmias Cardíacas/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cicatriz
7.
J Clin Med ; 12(3)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36769832

RESUMEN

Cardiac amyloidosis may result in an aggressive form of heart failure (HF). Cardiac contractility modulation (CCM) has been shown to be a concrete therapeutic option in patients with symptomatic HF, but there is no evidence of its application in patients with cardiac amyloidosis. We present the case of TTR amyloidosis, where CCM therapy proved to be effective. The patient had a history of multiple HF hospitalizations due to an established diagnosis of wild type TTR-Amyloidosis with significant cardiac involvement. Since he was highly symptomatic, except during continuous dobutamine and diuretic infusion, it was opted to pursue CCM therapy device implantation. At follow up, a significant improvement in clinical status was reported with an increase of EF, functional status (6 min walk test improved from zero meters at baseline, to 270 m at 1 month and to 460 m at 12 months), and a reduction in pulmonary pressures. One year after device implantation, no other HF hospital admission was needed. CCM therapy may be effective in this difficult clinical setting. The AMY-CCM Registry, which has just begun, will evaluate the efficacy of CCM in patients with HF and diagnosed TTR amyloidosis to bring new evidence on its potential impact as a therapeutic option.

9.
Europace ; 23(2): 264-270, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33212484

RESUMEN

AIMS: Ablation index (AI) is a marker of lesion quality during catheter ablation that incorporates contact force, time, and power in a weighted formula. This index was originally developed for pulmonary vein isolation as well as other left atrial procedures. The aim of our study is to evaluate the feasibility and efficacy of the AI for the ablation of the cavotricuspid isthmus (CTI) in patients presenting with typical atrial flutter (AFL). METHODS AND RESULTS: This prospective multicentre non-randomized study enrolled 412 consecutive patients with typical AFL undergoing AI-guided cavotricuspid isthmus ablation. The procedure was performed targeting an AI of 500 and an inter-lesion distance measurement of ≤6 mm. The primary endpoints were CTI 'first-pass' block and persistent block after a 20-min waiting time. Secondary endpoints included procedural and radiofrequency duration and fluoroscopic time. A total of 412 consecutive patients were enrolled in 31 centres (mean age 64.9 ± 9.8; 72.1% males and 27.7% with structural heart disease). The CTI bidirectional 'first-pass' block was reached in 355 patients (88.3%), whereas CTI block at the end of the waiting time was achieved in 405 patients (98.3%). Mean procedural, radiofrequency, and fluoroscopic time were 56.5 ± 28.1, 7.8 ± 4.8, and 1.9 ± 4.8 min, respectively. There were no major procedural complications. There was no significant inter-operator variability in the ability to achieve any of the primary endpoints. CONCLUSION: AI-guided ablation with an inter-lesion distance ≤6 mm represents an effective, safe, and highly reproducible strategy to achieve bidirectional block in the treatment of typical AFL.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Anciano , Aleteo Atrial/diagnóstico , Aleteo Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
10.
J Arrhythm ; 34(4): 402-409, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30167011

RESUMEN

BACKGROUND: Cavotricuspid isthmus (CTI) radiofrequency (RF) catheter ablation is the standard treatment for patients suffering from CTI-dependent atrial flutter (AFL). The aim of this study was to compare the use in clinical practice of 8-mm gold-tip catheter (8mmRFC) and open-irrigated gold-tip catheter (irrRFC) for RF typical AFL ablation. METHODS: Patients with typical AFL were treated with 8mmRFC or irrRFC catheters according to investigator preferences. The primary endpoint was the cumulative radiofrequency time (CRFT). Fluoroscopy time, acute and 6-month success rates were secondary endpoints. RESULTS: After excluding 3 patients with left AFL, 157 of the enrolled patients (median age 71.8 [interquartile range, 64.1-76.2], 76% men, 91% in NYHA class ≤II, 65% with no structural heart disease) were analyzed: 74 (47%) subjects were treated with the 8mmRFC and 83 (53%) with the irrRFC. The median CRFT was 3 [2-6] minutes in the 8mmRFC group and 5 [3-7] minutes in the irrRFC group (P = .183). There were no significant differences in ablation success rates, intraprocedural CTI reconnections, audible steam pops, and procedural times. In the 8mmRFC group, a significantly lower fluoroscopy time was observed as compared to the irrRFC group (8 [5-12] vs 15 [10-20] minutes, P < .001). During the follow-up period, AFL recurrences were documented in 3 patients in the 8mmRFC group and 2 in the irrRFC group (P = .655). CONCLUSIONS: The 8mmRFC and the irrRFC performed similarly in routine practice for CTI ablation in terms of cumulative RF time, acute and 6-month success rates. Fluoroscopy time was significantly lower in the 8mmRFC group.

11.
Pacing Clin Electrophysiol ; 40(3): 278-285, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27943358

RESUMEN

BACKGROUND: The traditional technique for subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, which involves three incisions and a subcutaneous pocket, is associated with possible complications, including inappropriate interventions. The aim of this prospective multicenter study was to evaluate the efficacy and safety of an alternative intermuscular two-incision technique for S-ICD implantation. METHODS: The study population included 36 consecutive patients (75% male, mean age 44 ± 12 years [range 20-69]) who underwent S-ICD implantation using the intermuscular two-incision technique. This technique avoids the superior parasternal incision for the lead placement and consists of creating an intermuscular pocket between the anterior surface of the serratus anterior and the posterior surface of the latissimus dorsi muscles instead of a subcutaneous pocket. RESULTS: All patients were successfully implanted in the absence of any procedure-related complications with a successful 65-J standard polarity defibrillation threshold testing, except in one, who received a second successful shock after pocket revision. During a mean follow-up of 10 months (range 3-30), no complications requiring surgical revision were observed. At device interrogation, stable sensing without interferences was observed in all patients. Two patients (5.5%) experienced appropriate and successful shock on ventricular fibrillation and in four patients (11%), a total of seven nonsustained self-terminated ventricular tachycardias were correctly detected. No inappropriate interventions were observed. CONCLUSIONS: Our experience suggests that the two-incision intermuscular technique is a safe and efficacious alternative to the current technique for S-ICD implantation that may help reducing complications including inappropriate interventions and offer a better cosmetic outcome, especially in thin individuals.


Asunto(s)
Músculos de la Espalda/cirugía , Desfibriladores Implantables , Insuficiencia Cardíaca/prevención & control , Implantación de Prótesis/métodos , Sistema de Registros , Adulto , Anciano , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
13.
Circ Arrhythm Electrophysiol ; 6(3): 606-13, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23685536

RESUMEN

BACKGROUND: Remote magnetic navigation-guided ablation with 3-dimensional (3D)-image integration could provide maximum benefit in patients with complex anatomy. We reviewed supraventricular tachycardia (SVT) ablation in adult patients with congenital heart disease to assess the contribution of these technologies. METHODS AND RESULTS: One hundred fifty-four SVT ablation procedures (228 SVTs) using a 3D-electroanatomic mapping system in 116 adult patients with congenital heart disease (mean age, 41; 76 male) were classified into 3 groups: Group A, manual mapping/ablation (n=60 procedures); Group B, remote magnetic navigation-guided mapping/ablation with normal femoral vein access (49); and Group C, remote magnetic navigation-guided mapping/ablation with difficult access (45). Group A included simple anomalies with less SVTs. Group B comprised predominantly Fontan patients with more SVTs. Group C included more complex defects, such as intra-atrial baffle or interrupted inferior venous access, in which retrograde aortic and superior venous accesses were used exclusively with more frequent use of image integration (97.8%; P<0.001). Acute success was 91.5%, 83.7%, and 82.2%, respectively (P=0.370). In group C, fluoroscopy time was the shortest (median, 4.2 min; P<0.001) despite the longer procedure duration (median, 253 min; P<0.001). SVTs free rates were 80.4%, 82.4%, and 75.8%, respectively (P=0.787) during a mean 20-months follow-up period. CONCLUSIONS: The combination of remote magnetic navigation, 3D-image integration, and electroanatomic mapping system facilitated safe and feasible ablation with very low fluoroscopy exposure even in patients with complex anomalies.


Asunto(s)
Ablación por Catéter , Cardiopatías Congénitas/cirugía , Imagenología Tridimensional , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Adulto , Análisis de Varianza , Mapeo del Potencial de Superficie Corporal , Cateterismo Cardíaco/métodos , Estudios de Cohortes , Electrocardiografía Ambulatoria/métodos , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Cuidados Posoperatorios , Pronóstico , Estudios Prospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas , Taquicardia Supraventricular/complicaciones , Resultado del Tratamiento
14.
Europace ; 15(6): 877-85, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23355132

RESUMEN

AIMS: We analysed the type and mechanism of supraventricular arrhythmias encountered in a series of symptomatic adults with atrial isomerism undergoing catheter ablation procedures. METHODS AND RESULTS: The study population included consecutive adults with atrial isomerism who had previously undergone surgical repair or palliation of the associated anomalies. Patients underwent electrophysiological study for symptomatic arrhythmia in our institution between 2010 and 2012 using magnetic navigation in conjunction with CARTO RMT and three-dimensional (3D) image integration. Eight patients (five females) with a median age of 33 years [interquartile range (IQR) 24-39] were studied. Access to the cardiac chambers of interest was obtained retrogradely via the aorta using remotely navigated magnetic catheters in six patients. Radiofrequency ablation successfully targeted twin atrioventricular (AV) nodal reentrant tachycardia in two patients, atrial fibrillation (AF) in three, focal atrial tachycardia (AT) mainly originating in the left-sided atrium in four patients, and macro-reentrant AT dependent on a right-sided inferior isthmus in three patients. The median fluoroscopy time was 3.0 min (IQR 2-11). After a median follow-up of 10 months (IQR 6-21), five of the ablated patients are free from arrhythmia; two patients experienced episodes of self-terminated AF and AT, respectively, within one month post-ablation; the remaining patient had only non-sustained AT during the electrophysiological study and was managed medically. CONCLUSION: Various supraventricular tachycardia mechanisms are possible in adults with heterotaxy syndrome, all potentially amenable to radiofrequency ablation. The use of remote magnetic navigation along with 3D mapping facilitated the procedures and resulted in a short radiation time.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Síndrome de Heterotaxia/diagnóstico , Síndrome de Heterotaxia/cirugía , Magnetismo/métodos , Cirugía Asistida por Computador/métodos , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Adulto , Femenino , Humanos , Masculino , Resultado del Tratamiento , Adulto Joven
15.
Echocardiography ; 29(3): 276-84, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22098539

RESUMEN

BACKGROUND: Although indexed left atrial volume (iLAV) is the most accurate measure of left atrial size, it has not been evaluated prospectively as predictor of recurrence of atrial fibrillation (AFib) after successful cardioversion (CV). METHODS: We prospectively selected 76 patients (mean age 66.1 ± 13.6 years, 65.8% men) with AFib who underwent successful CV. Baseline clinical and echocardiographic characteristics were obtained before CV. LAV was measured using Simpson's method and indexed to body surface area. All patients were scheduled for follow-up visit at 1, 6, 12 months, and then annually. A 24-hour Holter ECG was performed within 6 months and each time the patients reported symptoms suggestive of arrhythmia. RESULTS: The 52 patients (68.4%) with AFib recurrence had larger iLAV (35.5 ± 8.9 mL/m(2) vs 27.0 ± 6.7 mL/m(2) , P < 0.001). Anteroposterior LA diameter was not associated with AFib relapse (OR 1.08, 95% CI: 0.96-1.21, P = 0.09). Each unit increase in iLAV was associated with a 1.15-fold increased risk of recurrence (OR 1.15, 95% CI: 1.06-1.25, P < 0.001). In a multivariable model, iLAV remained the only independent predictor of relapse (adjusted OR 1.14, 95% CI: 1.02-1.28, P = 0.02). The area under ROC curves, generated to compare LA diameter, and iLAV as predictors of AFib recurrence were 0.56 (SE 0.07) versus 0.78 (SE 0.05), respectively (P = 0.003). CONCLUSION: This is the first prospective study to show that larger iLAV, as a more accurate measure of LA remodeling than anteroposterior diameter, is strongly and independently associated with a higher risk of AFib recurrence after CV.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/prevención & control , Ecocardiografía Tridimensional/métodos , Atrios Cardíacos/diagnóstico por imagen , Anciano , Femenino , Enfermedades de las Válvulas Cardíacas , Humanos , Masculino , Tamaño de los Órganos , Pronóstico , Reproducibilidad de los Resultados , Prevención Secundaria , Sensibilidad y Especificidad , Resultado del Tratamiento
16.
Eur J Echocardiogr ; 12(3): 214-21, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21149290

RESUMEN

AIMS: Atrial fibrillation (AFib) induces remodelling of the left atrium (LA). Indexed LA volume (iLAV) as more accurate measure of LA size has not been evaluated as predictor of recurrence of AFib after cardioversion. METHODS AND RESULTS: We identified 411 adults (mean age 64.1 ± 11.4 years, 34.5% women) who underwent successful cardioversion and with no history of other atrial arrhythmia, stroke, congenital heart disease, valvular dysfunction, surgery, thyroid dysfunction, acute or chronic inflammatory disease, and pacemaker. All echocardiographic data were retrieved from the laboratory database. iLAV was measured off-line using Simpson's method. Clinical characteristics and recurrence of clinical AFib were determined by review of medical records. Patients with scheduled follow-up of at least 6 months were included. About 250 patients (60.8%) developed AFib recurrence after a median (25th-75th percentile) follow-up of 345.0 (210.0-540.0) days. Patients with AFib recurrence had significantly greater iLAV than patients without AFib recurrence (39.7 ± 8.4 vs. 31.4 ± 4.6, P < 0.001). Each mL/m(2) increase in iLAV was associated with a 30% increased risk of AFib recurrence [odds ratio (OR) 1.30, confidence interval (CI) 1.23-1.38, P < 0.001]. In a multivariable model, each mL/m(2) increase in iLAV was independently associated with a 21% increase in the risk of AFib recurrence (OR 1.21, CI 1.11-1.30, P < 0.001). The areas under receiver operating characteristic curves, generated to compare LA diameter and iLAV as predictors of AFib recurrence, were 0.59 ± 0.3 and 0.85 ± 0.2, respectively (P < 0.001). CONCLUSION: The present study is the first to show that larger iLAV before cardioversion, as a more accurate measure of LA remodelling than LA diameter, is strongly and independently associated with higher risks of AFib recurrence.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Función del Atrio Izquierdo/fisiología , Volumen Cardíaco , Cardioversión Eléctrica/métodos , Atrios Cardíacos/patología , Anciano , Gasto Cardíaco/fisiología , Estudios de Cohortes , Intervalos de Confianza , Ecocardiografía/métodos , Electrocardiografía , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Curva ROC , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Volumen Sistólico/fisiología
17.
Med Devices (Auckl) ; 4: 157-67, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-22915942

RESUMEN

Population aging and broader indications for the implant of cardiac implantable electronic devices (CIEDs) are the main reasons for the continuous increase in the use of pacemakers (PMs), implantable cardioverter-defibrillators (ICDs) and devices for cardiac resynchronization therapy (CRT-P, CRT-D). The growing burden of comorbidities in CIED patients, the greater complexity of the devices, and the increased duration of procedures have led to an augmented risk of infections, which is out of proportion to the increase in implantation rate. CIED infections are an ominous condition, which often implies the necessity of hospitalization and carries an augmented risk of in-hospital death. Their clinical presentation may be either at pocket or at endocardial level, but they can also manifest themselves with lone bacteremia. The management of these infections requires the complete removal of the device and subsequent, specific, antibiotic therapy. CIED failures are monitored by competent public authorities, that require physicians to alert them to any failures, and that suggest the opportune strategies for their management. Although the replacement of all potentially affected devices is often suggested, common practice indicates the replacement of only a minority of devices, as close follow-up of the patients involved may be a safer strategy. Implantation of a PM or an ICD may cause problems in the patients' psychosocial adaptation and quality of life, and may contribute to the development of affective disorders. Clinicians are usually unaware of the psychosocial impact of implanted PMs and ICDs. The main difference between PM and ICD patients is the latter's dramatic experience of receiving a shock. Technological improvements and new clinical evidences may help reduce the total burden of shocks. A specific supporting team, providing psychosocial help, may contribute to improving patient quality of life.